$7240.20 (inc GST)
In Stock
Product Code: AMSWATERMAN
Brand: SMH
The AMS Water Management System is a compact and portable solution designed to deliver consistent water flow and filtration for decontamination facilities. It is built with durable materials and designed for efficient on-site handling.
Water Flow Capacity: Capable of producing a nominal 17 litres per minute to and from the decontamination shower, the unit supports continuous operation with reliable flow rate.
Filtration: Includes dual-stage filtration with 25 micron and 5 micron filters to help remove sediment and maintain clean water circulation.
Construction: The casing is constructed from seam-welded polypropylene and internally reinforced with welded ribs where needed for strength and durability.
Portability: Designed for easy movement by a single person, the unit is fitted with castor wheels and can pass through standard doorways.
Application: Suitable for both shower water supply and wastewater discharge in decontamination setups.
Specification | Details |
---|---|
Case | Polypropylene, seam welded |
Water Tank Size | 140 Litres |
Water Temperature | Variable Temperature Thermostat |
Filtration | 25 micron and 5 micron |
Use | Shower water supply and waste water discharge |
Hoses | Sold separately |
The AMS Water Management System supplies heated water to decontamination showers and manages the filtration of waste water through a 25 micron and a 5 micron filter. It's ideal for asbestos removal environments.
The system provides a nominal flow rate of 17 litres per minute to the showers.
The system uses dual-stage filtration with 25-micron and 5-micron filters to remove contaminants from the water.
The water tank holds up to 140 litres.
The system includes a variable thermostat for temperature control, with a secondary thermostat limiting max temperature to around 45°C.
Yes, it is compact, lightweight, and fitted with castors for easy transport through standard doorways.
It runs on a 230V, 50Hz supply with a maximum 10A current.
No, hoses are sold separately. The system supports various hose types with cam lock fittings.
Keep the unit clean and dry, check the power lead regularly, change filters under controlled conditions, and drain the tank between uses. A full service is recommended every six months.